In-depth guides on energy management, industrial protocols, and automation.
How to calculate chiller COP, EER and kW/ton: the role of flow and ΔT, IPLV/NPLV, sensor error and the limits of efficiency proxies without a flowmeter.
Read more → 21.09.2026Wrong data types, byte or word order and address offsets in a Modbus register map produce garbage values. Field-tested steps to verify every register.
Read more → 14.09.2026What sections does an energy audit report contain and how does the process work? Load profile, loss analysis, measures and the role of metering data.
Read more → 17.08.2026Monitor generator fuel use, run hours and test schedules with Argus EMS; early warnings protect hospital and data center critical power from outages.
Read more → 10.08.2026Two devices sharing a Modbus RTU slave ID cause collisions, CRC errors and timeouts. Learn how to detect and resolve address conflicts reliably.
Read more → 03.08.2026RS-485 multidrop bus wiring, 120 ohm termination resistor, fail-safe bias and A/B polarity: harden your Modbus RTU communication.
Read more → 27.07.2026Understand every line item on an industrial and MV electricity bill: active, reactive, demand, distribution and taxes. Which ones can you reduce?
Read more → 20.07.2026What is the capacity (demand) charge and how do you cut contract power, overshoot penalties and peak demand? A practical sizing guide.
Read more → 13.07.2026Lower electricity bills by shifting load away from peak hours. A guide to time-of-use tariffs, shiftable loads and demand management.
Read more → 06.07.2026Learn how to calculate transformer loading ratio, find the optimum load band and prevent overload damage with a worked example and action table.
Read more → 29.06.2026Guide to transformer winding and oil temperature monitoring: PT100 RTD selection, sensor placement, hot-spot modeling and early warning with Argus EMS.
Read more → 22.06.2026Dissolved gas analysis (DGA) detects partial discharge and overheating in transformer oil early; Argus EMS adds continuous monitoring and alarms.
Read more → 08.06.2026What does THD mean? How to interpret total harmonic distortion (THD-V, THD-I) results, typical thresholds, IEEE 519 limits and a step-by-step guide.
Read more → 07.06.2026What is transformer load ratio, how is it calculated, and why does continuous monitoring matter? Track transformer loading in real time with Argus EMS.
Read more → 07.06.2026Which parameters define UPS battery health, how is it measured, and how do you prevent early failure? Monitor battery status continuously with Argus EMS.
Read more → 07.06.2026How is reactive power compensation done step by step, how do you size a capacitor bank, and how is power factor corrected? Manage reactive power with Argus EMS.
Read more → 28.09.20261,000 TOE industry and building thresholds, energy management units, 4/7-year audits, ISO 50001 and end-of-March ENVER reporting.
Read more → 28.09.2026Tonne of oil equivalent explained: official Turkish factors, an electricity + gas example and the 1,000 TEP threshold.
Read more → 28.09.2026Day, peak and night bands, how the meter records T1/T2/T3 and when switching from single-time actually pays off.
Read more → 28.09.2026The EN 13757 M-Bus protocol: physical layer, primary/secondary addressing, unit loads, wM-Bus modes and common commissioning errors.
Read more → 28.09.2026The 2026 free consumer limit, SKTT thresholds and price formula, and why load profile data matters when switching.
Read more → 05.06.2026Learn capacitor bank maintenance step by step and keep reactive power management secure with Argus EMS.
Read more → 05.06.2026Explore the differences, advantages, and right selection criteria for passive and active harmonic filters from the Argus EMS perspective.
Read more → 27.05.2026What is ISO 50001 and what are its requirements? Certification benefits, EnPI monitoring, and the ISO 50001 compliance infrastructure with Argus EMS.
Read more → 27.05.2026The factors that determine a power transformer's lifespan: temperature, load profile, harmonic distortion. Methods to extend transformer life with the IEEE C57.91 6°C rule and proactive monitoring.
Read more → 27.05.2026What is harmonic distortion in the electrical grid and how does it arise? The effects of THD on transformers, capacitor banks, and equipment. The IEEE 519 standard and harmonic filtering methods.
Read more → 26.05.2026How do you save energy in factories, shopping malls, and hospitals? Cost reduction methods through reactive power optimization, peak shaving, tariff management, and VFDs.
Read more → 25.05.2026Why is uninterruptible power supply (UPS) monitoring critical? Tracking APC, Eaton, and Socomec UPS units via SNMP and Modbus. Battery capacity and alarm management.
Read more → 24.05.2026What is a power meter and what does it measure? A comparison of the Schneider PM5350, Siemens PAC3200, and ABB B series. An EMS integration guide over Modbus TCP.
Read more → 23.05.2026What is the MQTT protocol and how does the pub/sub model work? QoS levels, TLS security, and energy data transmission over MQTT in Argus EMS.
Read more → 22.05.2026What is the Modbus TCP protocol and how does it work? The difference from Modbus RTU, function codes, connecting a power meter, and Argus EMS integration.
Read more → 18.05.2026What is OSOS, how does it work, and how does it differ from an industrial EMS? The EPDK OSOS mandate and its scope in Türkiye.
Read more → 10.05.2026Power transformer monitoring: load ratio, temperature, and THD tracking. A comprehensive technical guide to preventing unplanned outages.
Read more → 01.05.2026EPDK inductive (20%) and capacitive (15%) reactive energy limits, along with prevention methods using power factor correction and an EMS.
Read more →Explore the system with your own data in a demo session.